Mission-critical Infrastructure


 Home  ›  Products  ›  Precision Cooling

Precision Cooling: Beat the Heat

Ensuring the proper environment for IT systems is essential to maintaining high availability.  Regardless of application, IT equipment produces heat that can be damaging to both uptime and longevity of your investment.

Altruent's cooling solutions by APC are tailored to meet the needs of your environments, from wiring closets and computer rooms to data centers of all sizes.  Scalable solutions, including air distribution/fans, portables, and precision cooling systems, are available to provide the right solution to meet the unique cooling requirements your environment demands.

Some of our cooling solutions include:

  • NetworkAir PA
    • Range: 1.6kW or 3.9kW
    • Portable, self-contained air conditioning solution for small rooms and data closets
    • Air Filtration removes dirt and other particles for clean air supply
    • On/Off Scheduling allows the user to control unit to save energy costs
    • Network Interface provides management via web, SNMP, or Telnet
    • Condensate pump and duct kit included 
NetworkAirPA

 

  • InfraStruXure InRow SC  (self-contained)
    • Range: up to 7kW
    • Rapidly deployable, in-row air conditioning for server rooms and wiring closets
    • Self-contained design allows for fast installation without refrigerant lines or remote heat exchangers
    • In-Row architecture provides increased cooling performance
    • Modular design provides scalable solution to add cooling as demand increases
    • Network Interface provides management via web, SNMP, or Telnet
    • Hot swappable fans allow system to remain operation if a fan replacement is required

inrowsc.jpg           inrowscrear

                               Front                            Rear

  • InfraStruXure InRow RD  (air cooled or fluid cooled)

    • Range: up to 12kW
    • In-Row precision air conditioning for wiring closets, server rooms, and data centers
    • Hot-swappable fans allow unit to remain operation if a fan replacement is needed
    • Modular design provides scalable solution to add cooling units as demand increases
    • Available in both air-cooled and fluid cooled (water/glycol) versions
    • Rack inlet control guarantees inlet temperate to IT equipment

InRowRD

 

  • InfraStruXure InRow RC  (chilled water only)

    • Range: up to 30kW
    • In-Row precision air conditioning for medium to large data centers and high density applications
    • Draws power from UPS for cooling protection with dual feeds for redundancy
    • Hot-swappable fans allow unit to remain operational if a fan replacement is required
    • Modular design provides scalable solutions to add cooling as demand increases
    • Variable speed fans reduce energy consumption during off-peak cooling periods
    • Rack inlet control guarantees inlet temperature to IT equipment

InRowRCFront                 InRow RC rear view

                               Front                                 Rear

  • InfraStruXure InRow RP
    • Range: up to 70kW
    • In-Row precision air conditioning for medium to large data centers including high density applications
    • Predictable Cooling - Placing the unit in the row of racks moves the source of cooling closer to the heat load.  This eliminates air mixing and provides a predictable cooling architecture.
    • Scalable Densities - The in-row architecture cools densities of 1-5kW per racks.  Densities up to 20kW per rack can be achieved by implementing the Hot-aisle containment system.
    • Increased Capacity - Warmer entering air temperatures result in increased cooling capacity, required fewer cooling units than traditional cooling methodologies.
    • Network Interface - Provides management via web browser by connecting the device directly to the network.
    • Front Service Access - Full service, front access for routine servicing of components

                        InRow RP          InRow RP rear view

 

Data center cooling has become increasingly unpredictable due to the use of blade servers and other high-density equipment.  APC promotes in-row cooling, where the cooling unit is moved closer to the source of heat generation, and containing the hot-aisles of the data centers to address this challenge.

 

  InfraStruXure



 

 

 

 

 

 

 

 

 

  

 

  

 

 

      InRowSCApp

InRow SC and NetShelter SX rack

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

  

 
 

 

 

 ISXT120
Symmetra PX UPS and populated NetShelter SX rack with InRow RC precision cooling unit shown

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  


 

 

 